4 web server (http) interface, 1 enable the web server interface – Comtech EF Data LPOD-R User Manual
Page 93
LPOD-R Outdoor Amplifier / Block Up Converter
MN-LPODR
Ethernet-based Remote Product Management
Revision 1
4–7
4.4
Web Server (HTTP) Interface
A user-supplied web browser allows the full M&C of the LPOD-R through its Web Server
Interface. This embedded web application is designed for use with Microsoft’s Internet Explorer
Version 5.5 or higher. It is a non-secure web application.
See the Remote Commands and Queries specifications tables in Chapter 5. OPTIONAL SERIAL-
BASED REMOTE PRODUCT MANAGEMENT for more information.
4.4.1 Enable the Web Server Interface
To enable the Web Server Interface in the LPOD-R using only a 100BaseTx remote interface
running a Microsoft Windows OS:
1. Select Start, then Run, then type
cmd.
2. Click OK to open the command
prompt window.
3. Start a Telnet session with the
unit at the default IP address of
192.168.1.4.
4. Enter the Telnet username and
password. The default for both
parameters is Comtech.
5. Set the remote access parameter
to accept Ethernet remote
control using the LRS command.
LRS=3, the default remote
command, provides Serial +
Ethernet control, while remote
command LRS=2 provides
Ethernet control only.
You must assign a unique IP Address for each unit on the network before connecting to an
existing network. The IP address may need to be changed from the factory default setting.