Comtech EF Data LPOD-R User Manual
Page 128
LPOD-R Outdoor Amplifier / Block Up Converter (BUC)
MN-LPODR
Optional Serial-based Remote Product Management
Revision 1
5–18
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments
for Command
or Response
to Query
Description of Arguments
(Note that all arguments are printable ASCII characters)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response to
Query
(Target to
Controller)
Number of
Unread
stored Events
N/A
3 bytes
Query only.
Returns the number of stored events that remain unread, in the form xxx.
Example: <1/NUE?’cr’
>0001/NUE=126’cr’’lf’
NUE=
NUE?
NUE=xxx
Number of
Unread
stored
Statistics
N/A
3 bytes
Query only.
Returns the number of stored statistics that remain unread, in the form xxx.
Example: <1/NUS?’cr’
>0001/NUS=126’cr’’lf’
NUS=
NUS?
NUS=xxx
Part Number
N/A
96 bytes
alphanumeric
Query Only
Returns the DOTCODE string that was loaded into the unit.
Example: <1/PNM? ’cr’
>0001/PNM=HPODC0.350WRSW00’cr’’lf’
PNM=
PNM?
PNM *
PNM?
PNM=x….x
(See Description
of Arguments for
details)
Retrieve
Alarm Status
N/A
168 bytes
Query only.
Returns the Alarm status of the unit, where:
OK = no fault condition
FT = faulted
AL = alarm
YS = Yes
NO = No
MS = masked
NA = unused
Example:
<1/RAS?’cr’
>0001/RAS=’cr’
LINEV=OK’cr’ input LINE voltage
LINEA=OK’cr’ input LINE amperage
LNBVT=NA’cr’ +13/18V LNB power supply
P13VT=NA’cr’ +13.5V power supply
P10V1=NA’cr’ +10V power supply
A10V1=NA’cr’ +10V1 RF supply
A10V2=NA’cr’ +10V2 RF supply
P7V8T=NA’cr’ +7.8V power supply
P5V8T=OK’cr’ +5.8V power supply
P2V5T=NA’cr’ +2.5V power supply
P1V2T=OK’cr’ +1.2V power supply
N5V8T=AL’cr’ -5.8V power supply
FANV=OK’cr’ Fan voltage
FANA=OK’cr’ Fan current
ATEMP=OK’cr’ Amplifier temperature
RAS=
RAS?
RAS=x….x
(See Description
of Arguments for
details)