Comtech EF Data LPOD-R User Manual
Page 134
LPOD-R Outdoor Amplifier / Block Up Converter (BUC)
MN-LPODR
Optional Serial-based Remote Product Management
Revision 1
5–24
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments
for Command
or Response
to Query
Description of Arguments
(Note that all arguments are printable ASCII characters)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response to
Query
(Target to
Controller)
Set RTC
Time
TIM=
6 bytes
Command or Query.
Sets or returns the time, from midnight, in the form hhmmss, where:
hh = hours, from 00 to 23
mm = minutes, from 00 to 59
ss = seconds, from 00 to 59
Examples: (time = 23 hours, 12 minutes and 59 seconds since midnight – i.e., 11:12:59 PM):
Command Example: <1/TIM=231259’cr’
>0001/TIM=’cr’’lf’
Query Example: <1/TIM?’cr’
>0001/TIM=231259’cr’’lf’
TIM=
TIM?
TIM *
TIM?
TIM=xxxxxx
(Same format as
command
arguments)
Temperature
N/A
5 bytes
Query only.
Returns the temperatures of the Heatsink in the form sxxx, where:
s = sign byte (plus + or – minus)
xxxx = the temperature.
Example: <1/TMP?’cr’
>0001/ TMP=+26.0’cr’’lf’
TMP=
TMP?
TMP=sxx xx
(See Description
of Arguments for
details)
Terminal
Status
Change
N/A
1 byte
Query only.
Returns the change in configuration since the last time the query was issues in the form x, where:
x = 0 (no status change) or 1 (a status change has occurred)
Example: <1/TSC?’cr’
>0001/TSC=0’cr’’lf’
Notes:
1) A status change is defined as any time a parameter is changed, e.g., when a command that changes a value is
successfully executed. A status change also results when there is a redundant switchover, or a fault condition.
2) A query does not set the status change flag.
3) The status change flag clears after being read.
TSC=
TSC?
TSC=x
(See Description
of Arguments for
details)