Comtech EF Data LPOD-R User Manual
Page 123
LPOD-R Outdoor Amplifier / Block Up Converter (BUC)
MN-LPODR
Optional Serial-based Remote Product Management
Revision 1
5–13
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments
for Command
or Response
to Query
Description of Arguments
(Note that all arguments are printable ASCII characters)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response to
Query
(Target to
Controller)
Set RTC
(Real-Time-
Clock) Date
DAY=
6 bytes
Command or Query.
Sets or returns the date in the form ddmmyy, where:
dd = day of the month, between 01 and 31
mm = month of the year, between 01 and 12
yy = year, between 00 and 99 (2000 to 2099)
Example (date = April 24, 2013):
<1/DAY=240413’cr’
>0001/DAY=’cr’’lf’
DAY=
DAY?
DAY*
DAY?
DAY=ddmmyy
(Same format as
command
arguments)
Enable
Statistics
Averaging
ESA=
1 byte
Command or Query.
Enables or Disables averaging of statistics data at a rate of once per second for 10 seconds. If Disabled, burst values will
be logged instead of averaged values. Command/query is in the form x, where:
0 = Disable
1 = Enable
Default Value: 0
Example: <1/ESA=0’cr’
>0001/ESA=’cr’’lf’
ESA=
ESA?
ESA*
ESA?
ESA=x
(Same format as
command
arguments)
Firmware
Accept /
Reject
FAR=
1 byte
Command or Query.
Accepts or Rejects the Active firmware Image in the form x, where:
A= Accept
R= Reject
Example: <1/FAR=A’cr’
>0001/FAR=’cr’’lf’
Notes:
1) Accept forces the LPOD-R to de-assert the Unaccepted Firmware Fault (UFF) generated by upload of the Pending
firmware Image to the Active firmware Image, and allows subsequent power-cycles/reboots to occur without affecting
the firmware image.
2) Reject causes the image to be erased on the next power cycle/reboot, and instructs bootmgr to wait until a new
firmware image load is FTPed into the Pending firmware Image.
FAR=
FAR?
FAR*
FAR?
FAR=x
(Same format as
command
arguments)