Comtech EF Data LPOD-R User Manual
Page 120
LPOD-R Outdoor Amplifier / Block Up Converter (BUC)
MN-LPODR
Optional Serial-based Remote Product Management
Revision 1
5–10
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments
for Command
or Response
to Query
Description of Arguments
(Note that all arguments are printable ASCII characters)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response to
Query
(Target to
Controller)
Concise
Alarm Status
Concise
Alarm Status
(cont)
N/A
44 bytes
Query only.
Returns the Alarm status of the unit. This is the concise version of the RAS command, response is semicolon delimited, in
the form a;b;c;d;e;f;g;h;i;j;k;I;m;n;o;p;q;r;s;t;u;v;w;x;y;z;aa’cr’’lf’ where:
a thru z = 0, 1, 2, 3, 4, or 5
0 = FT
1 = OK
2 = AL
3 = NO
4 = YS
5 = MS
a = LINEV
b = LINEA
c = LNB Power Supply (N/A)
d = +13.5V Power Supply (N/A)
e = +10V Power Supply
f = +10V1 Amplifier Power Supply
g = +10V2 Amplifier Power Supply (N/A)
h = +7.8V Power Supply (N/A)
i = +5.8V Power Supply
j= +2.5V Power Supply (N/A)
k = +1.2V Power Supply
l = -5V Power Supply
m = Fan1V
n = Fan1A
o = Heatsink Temp
p = Overtemp Shutdown
q = llC Status
r = Forward Power Alarm
s = Flash Checksum
t = FPGA Done (N/A)
u = BUC Lock Detect
v = External Ref Lock Detect (N/A)
w = LNB Current (N/A)
x = Redundant Switch Condition (N/A)
y = Redundant Link Status (N/A)
z = Terminal Status Change
aa = Unaccepted Firmware
Note: Field values appear only if the appropriate model/options are selected/installed. Otherwise, the unused fields display
NA.
CAS=
CAS?
CAS=x….x
(See Description
of Arguments for
details)