Comtech EF Data LPOD-R User Manual
Page 119
LPOD-R Outdoor Amplifier / Block Up Converter (BUC)
MN-LPODR
Optional Serial-based Remote Product Management
Revision 1
5–9
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments
for Command
or Response
to Query
Description of Arguments
(Note that all arguments are printable ASCII characters)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response to
Query
(Target to
Controller)
Auto Fault
Recovery
AFR=
1 byte
Command or Query.
Enables or disables Auto Fault Recovery. The LPOD output is automatically muted if any of the following fault conditions
occur: BUC lock detect fault, LNB current fault (see Note), or LNB voltage fault (see Note). If enabled, auto fault recovery
causes the output to return to its pre-fault mute condition if all faults are cleared. If disabled, the output remains muted even
if all faults are cleared. Command/query is in the form x, where:
0 = Disable
1 = Enable
Default Value: 1
Example: <1/AFR=1’cr’
>0001/AFR=’cr’’lf’
Note: This fault can be user-defined as fault, alarm, or masked (see MSK command for more info).
AFR=
AFR?
AFR*
AFR?
AFR=x
(Same format as
command
arguments)
Attenuation
ATT=
5 bytes
Command or Query.
Sets or returns the attenuation level, in dB, in the form xx.xx, where:
xx.xx = 00.00 to 20.00 in 0.25 dB steps.
Default Value: 10.00
Example: <1/ATT=12.25’cr’
>0001/ATT=’cr’’lf’
ATT=
ATT?
ATT*
ATT?
ATT=xx.xx
(Same format as
command
arguments)
Clear All
Stored
Alarms
E
CAA=
None
Command only.
Instructs the unit to clear all Stored Alarms. This command takes no arguments.
Example: <1/CAA=’cr’
>0001/CAA=’cr’’lf’
CAA=
CAA*
N/A
N/A
Clear All
Stored
Events
CAE=
None
Command only.
Instructs the BUC to clear all Stored Events. This command takes no arguments.
Example: <1/CAE=’cr’
>0001/CAE=’cr’’lf’
CAE=
CAE*
N/A
N/A