Comtech EF Data LPOD-R User Manual
Page 131
LPOD-R Outdoor Amplifier / Block Up Converter (BUC)
MN-LPODR
Optional Serial-based Remote Product Management
Revision 1
5–21
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments
for Command
or Response
to Query
Description of Arguments
(Note that all arguments are printable ASCII characters)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response to
Query
(Target to
Controller)
Retrieve
Maintenance
Status (cont)
N/A
213 bytes
alphanumeric
Example: <1/RMS?’cr’
>0001/RMS=
LINEV=046.9
LINEA=000.3
LNBVT=XXXXX
P13VT=XXXXX
P10V1=010.5
A10V1=XXXXX
A10V2=XXXXX
P7V8T=XXXXX
P5V8T=006.1
P2V5T=XXXXX
P1V2T=001.3
N5V8T=-03.6
FAN1V=010.3
FAN1A=011.6
BUCVT=XXXXX
FWPWR=<24.0
REFVT=XXXXX
LNBCS=XXXXX
ATEMP=028.0
OTEMP=011.0
Note: LNBVT, FANR2, A10V2, BUCVT, REFVT, LNBCS, and OTEMP display when the appropriate options are installed;
Otherwise, the value fields shall be padded with X’s
Retrieve Next
5 unread
stored
Events
N/A
75 bytes
Query only.
Unit returns the oldest 5 Stored Events that have not yet been read over the remote control. Reply format: {CR}Sub-
body{CR}Sub-body{CR}Sub-body{CR} Sub-body{CR}Sub-body, where Sub-body= ABCCddmmyyhhmmss:
A = Fault/clear indicator:
F=Fault
C=Clear
I=Info
B = Fault type:
1=Unit
2=RF
3=Log
CC = Fault Code numbers (as in RAS?) or Info Code:
0=Power Off
1=Power On
2=Log Cleared
3=Global Config Change
4=Redundancy Config Change
RNE=
RNE?
RNE={CR}ABC
Cddmmyyhhmm
ss{CR}ABCCdd
mmyyhhmmss{
CR}ABCCddmm
yyhhmmss{CR}
ABCCddmmyyh
hmmss{CR}ABC
Cddmmyyhhm
mss
(See Description
of Arguments for
details)