Installation
DD2401 VME L-Band Demodulator Card Installation & Operational Manual
2-2
MN-VME2401 – Rev. B
The connector definitions and pinout tables are shown in section 5.0. Any connection interfacing
to the modem must be the appropriate mating connector.
Shielded cables with the shield terminated to conductive backshells are required in
order to meet EMC directives. Cables with insulation flammability ratings of 94 VO or
better are required in order to meet Low Voltage Directives.
2.4.2 Factory Terminal Setup (Refer to Section 4.4)
The factory terminal setup is as follows:
Emulation Type:
VT-100 (can be changed)
Baud Rate:
19200
Data Bits
8
Parity:
No Parity (Fixed)
Stop Bits:
1
2.4.3 Remote Protocol Factory Default Setup
Demodulator will be configured with default settings when they are shipped from factory. Refer to
Section 5-6 to Defaults setting can be modified may be the default settings for the RS485
Communication port are:
Table 2-1. S1 DIP Switches
Demodulator
Position
1
Position
2
Position
3
Position
4
Address in
Decimal
Demodullator
on
off
off
off
33
2.5
Storage
It is recommended that the unit be stored in its original sealed packaging. The unit should be
stored in a dry location where the temperature is stable, away from direct contact with rain, snow,
wind, sun or anything that may cause damage.