beautypg.com

3 faults/alarms: type 1 operation – Comtech EF Data SDM-100A User Manual

Page 95

background image

SDM-100A Satellite Modem

Operation

Rev. 0

3–61

3.2.2.3 Faults/Alarms: Type 1 Operation

The Faults/Alarms level is accessible from the Function Select menu. Faults/Alarms are
similar to Monitor functions. The Faults/Alarms level displays the current fault status of
the group being displayed. Press [

] or [

] to move between the Faults/Alarm groups:

• Modulator

faults

• Demodulator

faults

• Transmit interface faults

• Receive interface faults

• Common equipment faults


The current faults/alarms status is displayed on line 2 of the display in real time. Fault
status is displayed as a “+” or “-” for each parameter monitored:

• “-” indicates that no fault or alarm exists.

• “+” indicates that a fault exists, and will cause switching in a redundant system.

• A reversed contrast “+” indicates an alarm is active, but will not cause switching

to occur.


To display labels for individual faults or alarms, press [ENTER]. Press [

] or [

] to move

the flashing cursor to the fault or alarm to be identified. The label for that fault/alarm is
immediately displayed on line one of the display. [CLEAR] can be used to exit this level
of operation and return to the previous level.