Comtech EF Data SDM-100A User Manual
Page 176
Remote Control Operation
SDM-100A Satellite Modem
A–24
Rev. 0
"APD_" command).
(Note 1)
p43 = n, where 'n' is '0' (off) or '1' (on).
Parameter 44 (p44): ADPCM Subscriber/Trunk Emulation
(ref. "SBTR_" command).
(Note 1)
p44 = n, where 'n' is '0' (Subscriber) or '1' (Trunk).
Parameter 45 (p45): ADPCM E & M Signal Type (ref.
"EMS_" command).
(Note 1)
p45 = n, where 'n' is '1', '2', '3', '4', or '5' (signal type).
Parameter 46 (p46): ADPCM Encoding Law (ref. "LAW_"
command).
(Note 1)
p46 = n where 'n' is 'A' (A-Law ) or 'U' (u-Law)
Parameter 47 (p47): Off hook alert enable (ref. "HOOK_"
command).
(Note 1)
p47 = n, where 'n' is '0' (off) or '1' (on).
Parameter 48 (p48): ADPCM Transmit Service Channel
Level (ref. "ISCL_" command).
(Note 1)
p48 = nnn, service channel level in dBm.
Parameter 49 (p49): ADPCM Receive Service Channel
Level (ref. "ISCL_" command).
(Note 1)
p49 = nnn, service channel level in dBm.
Parameter 50 (p50): ADPCM RS-422 Send Data Signal
Programming (ref. "SD_" command).
(Note 1)
p50 = n, where 'n' is '0' (NORMAL) or '1' (INVERT).
Parameter 51 (p51): ADPCM RS-422 Receive Signal
Programming (ref. "RD_" command).
(Note 1)
p51 = n, where 'n' is '0' (NORMAL) or '1' (INVERT).
Parameter 52 (p52): ADPCM RS-422 Receiver Ready
Signal Programming (ref. "RR_" command).
(Note 1)
p52 = n, where 'n' is '0' (NORMAL) or '1' (INVERT).
Parameter 53 (p53): ADPCM RS-422 Data Mode Signal
Programming (ref. "DM_" command).
(Note 1)
p53 = n, where 'n' is '0' (NORMAL) or '1' (INVERT).
Parameter 54 (p54): ADPCM Audio Loopback Jumper
Status (ref. "ALBJ_" command).
(Note 1)
p54 = n, where 'n' is '0' (off) or '1' (on).
Parameter 55 (p55): RTS TX-IF Control Mode (ref.
"RTSM_" command).
(Note 1)
p55 = n, where 'n' is '0' (off) or '1' (on).
Parameter 56 (p56): ASYNC Communications
programming ON/OFF (ref. "ASP_" command). (Note 2)
p56 = n, where 'n' is '0' (off) or '1' (on).
Parameter 57 (p57): Interface Loop Timing (ref. "ILT_"
command).
(Note 3)
p57 = n, where 'n' is '0' (off) or '1' (on).
Parameter 58 (p58): ASYNC TX Overhead Baud Rate (ref.
"TOBR_" command).
(Note 3)
p58 = nnnnn, where 'nnnnn' is the currently
programmed baud rate.
Parameter 59 (p59): ASYNC TX Channel Char. Length (ref.
"TCCL_" command).
(Note 3)
p59 = n, where 'n' is the currently programmed
character length.
Parameter 60 (p60): ASYNC TX Channel Stop Bits (ref.
"TCSB_" command).
(Note 3)
p60 = n, where 'n' is the current number of stop bits
programmed.
Parameter 61 (p61): ASYNC TX Channel Parity (ref.
"TOCP_" command).
(Note 3)
p61 = xxxx, where 'xxxx' is the currently programmed
parity.
Parameter 62 (p62): ASYNC RX Overhead Baud Rate (ref.
"ROBR_" command).
(Note 3)
p62 = nnnnn, where 'nnnnn' is the currently
programmed baud rate.
Parameter 63 (p63): ASYNC RX Channel Char. Length
(ref. "RCCL_" command).
(Note 3)
p63 = n, where 'n' is the currently programmed
character length.
Parameter 64 (p64): ASYNC RX Channel Parity (ref.
"ROCP_" command).
(Note 3)