A.5 Stored Faults

Information on stored faults is returned when requested. If no stored fault exists for a given fault number,
the words “NO Fault” will be returned instead of the normal time/date status information.

The following symbols are commonly used to define the stored faults status commands:

• #

Fault number (0 to 9). “0” is the first fault stored.

• hh

Hours in 24-hr. format.

• mm Minutes.

• ss

Seconds.

• MM Month.

• DD Day.

• YY Year.

Modulator
Stored
Faults

Command:
Response:

>add/MSF_# hh:mm:ss MM/DD/YY'cr'
MOD_xxx'cr'
SYN_xxx'cr'
DCS_xxx'cr'
ICH_xxx'cr'
QCH_xxx'cr'
AGC_xxx'cr''lf']



Module (OK/FLT)
IF Synthesizer (OK/FLT)
Data Clock Synthesizer (OK/FLT)
I Channel (OK/FLT)
Q Channel (OK/FLT)
AGC Level (OK/FLT)

Demodulato
r Stored
Faults

Command:
Response:

>add/DSF_# hh:mm:ss MM/DD/YY'cr'
MOD_xxx'cr'
CD_xxx'cr'
SYN_xxx'cr'
ICH_xxx'cr'
QCH_xxx'cr'
DSCR_xxx'cr'
BERT_xxx'cr''lf']



Demod Module (OK/FLT)
Carrier Detect (OK/FLT)
IF Synthesizer Lock (OK/FLT)
I Channel (OK/FLT)
Q Channel (OK/FLT)
Descrambler (OK/FLT)
BER Threshold (OK/FLT)

Interface
Transmit
Side Stored
Faults

Command:
Response:

>add/ITSF_# hh:mm:ss MM/DD/YY'cr'
CLK_xxx'cr''lf']
TAC_xxx'cr' (See

Note)




Selected Transmit Clock Activity (OK/FLT)
Transmit Audio Clip (OK/FLT)

Note: Status only returned when ADPCM board is installed.

Interface
Receive
Side Stored
Faults

Command:
Response:

>add/IRSF_# hh:mm:ss MM/DD/YY'cr'
CLK_xxx'cr'
UNFL_xxx'cr'
OVFL_xxx'cr''lf']
RAC_xxx'cr' (See

Note)

DMXL_xxx'cr' (See

Note)

HOOK_xxx'cr' (See

Note)



Selected Buffer Clock Activity (OK/FLT)
Buffer Underflow (OK/FLT)
Buffer Overflow (OK/FLT)
Receive Audio Clip (OK/FLT)
Demultiplexer Lock (OK/FLT)
Remote Off Hook Fault (OK/FLT)

Note: Status only returned when ADPCM board is installed.

Common
Equipment
Stored
Faults

Command:
Response:

>add/CSF_# hh:mm:ss MM/DD/YY'cr'
M&C_xxx'cr'
INT_xxx'cr'
BAT_xxx'cr'
+5_xxx'cr'
+12_xxx'cr'
-12_xxx'cr''lf']



Monitor & Control Module (OK/FLT)
Data Interface Module (OK/FLT)
Battery/Clock (OK/FLT)
+5V Power Supply (OK/FLT)
+12V Power Supply (OK/FLT)
-12V Power Supply (OK/FLT)