2.4.3 Faults (J7)
The Fault connector on the modem is used to interface FORM-C contact closures for the
purpose of fault reporting. There are three FORM-C summary fault contacts:
• Modulator
• Demodulator
• Common
equipment
For further discussion on the monitored faults, refer to Chapter 3.
To obtain a system summary fault, connect all FORM-C contacts in parallel.
The fault interface is provided on a 9-pin female D connector. Screw locks are provided
for mechanical security on the mating connector.
Pin #
Name
Function
1
NO
Common Equipment is OK
2 COM
3
NC
Common Equipment is FAULTED
4
NO
Modulator is OK
5 COM
6
NC
Modulator is FAULTED
7
NO
Demodulator is OK
8 COM
9
NC
Demodulator is FAULTED
Note: A connection between the Common (COM) and Normally Open (NO) contacts
indicates no fault.
2.4.4 TX IF Output (CP1)
This is the transmit IF connector. The output impedance is 75
Ω
(50
Ω
optional), and the
output power level is -5 to -30 dBm, in 0.1 dB steps.
For normal operation, the output will be a QPSK modulated result of the DATA I/O
connector, between 50 and 180 MHz.