Comtech EF Data SDM-100A User Manual
Page 22
Introduction
SDM-100A Satellite Modem
1–6
Rev.
0
Additional Modulator Specifications
Output Power
-5 to -30 dBm, adjustable in 0.1 dB steps.
Output Spurious and Harmonics
-55 dBc in 4 kHz BW in-band (50 to 180 MHz).
-55 dBc in 4 kHz BW out-of-band (0 to 500 MHz).
Output Impedance
75
Ω
standard, or 50
Ω
optional.
Output Return Loss
20 dB.
Output Frequency Stability
±
10 PPM.
Data Clock Source
Internal or external.
External clock,
±
100 PPM and < 5
%
jitter.
Internal Data Clock Stability
±
10 PPM.
Additional Demodulator Specifications
Input Power (Desired Carrier)
-30 to -55 dBm (composite).
+30 dB power within 2 MHz from desired carrier.
+40 dB power outside of 2 MHz from desired carrier.
-5 dBm maximum composite.
Input Impedance
75
Ω
standard, or 50
Ω
optional.
Input Return Loss
20 dB.
Carrier Acquisition Range
±
25 kHz minimum.
Clock Acquisition Range
±
100 PPM.
Acquisition Time
< 1 second typical at 64 kbit/s.
Directed Sweep:
Sweep Range
0 to 70000 Hz.
Sweep Center
-35000 to +35000 Hz.
Remote Control Specifications
Serial Interface
RS-232-C or RS-485, Baud Rate 110 to 19,200 bit/s.
Protocol not necessarily compatible with SDM-650B or
SDM-308B.
Signals Controlled/Monitored
Transmit Frequency.
Receive
Frequency.
Transmit
Power.
Transmitter
On/Off.
Data Rate Select.
IF
Loopback.
RF
Loopback.
Baseband
Loopback.
Scrambler
On/Off.
Descrambler
On/Off.
Sweep
Range.
Sweep
Center.
Filter
Mask.
Raw Error Rate.
Corrected Bit Error Rate.
Receive
E
b
/N
0
.
TX Clock Internal/External.
RX Clock Normal/Invert.
Receive Signal Level.
Receive Carrier Detect.
Power Supply Voltages.
Fault
Status.
Stored Fault Status.
Configuration Retention
Will maintain current configuration for up to one year
minimum without power.
Addressing
Programmable to 1 of 255 possibilities.
Address 0 reserved for global addressing.
Local control of all remote functions included via push-button entry.