4 configuration local aupc – Comtech EF Data SDM-100A User Manual
Page 57
SDM-100A Satellite Modem
Operation
Rev. 0
3–23
3.2.1.1.4 Configuration Local AUPC
AUPC Enable
This option turns the local modem’s AUPC ON or OFF.
Nominal Power
This option programs the nominal power set point for AUPC from -30
to -5 dBm.
Minimum Power
This option programs the minimum power set point for AUPC from -
30 to -5 dBm.
Maximum Power
This option programs the maximum power set point for AUPC from -
30 to -5 dBm.
Target Noise
This option programs the target E
b
/N
0
setpoint. The E
b
/N
0
setpoint
can range from 3.2 to 9.7 dB, in 0.1 dB increments.
Tracking Rate
This option programs the maximum tracking rate. The maximum
tracking rate can range from 0.5 to 6.0 dBm per minute.
Local CL Action
This option programs the action taken by the local modem if Carrier
Loss is detected. The local CL can be programmed to Maximum,
Nominal, or Hold.
Remote CL Action
This option programs the action taken by the remote modem if
Carrier Loss is detected. The remote CL can be programmed to
Maximum, Nominal, or Hold.