B.2.3 specifications – Comtech EF Data SDM-100A User Manual
Page 200
Options
SDM-100A Satellite Modem
B–18
Rev.
0
B.2.3 Specifications
Voice Encoding
Audio Encoding
CCITT G.711 and G.721 PCM or ADPCM
Audio Encoding Rate
64, 32, or 16 kbit/s (user-selectable)
Audio Encoding Type
CCITT G.711 A-Law or
µ-Law (user-selectable)
Voice Interface
Audio Interface Type
600
Ω Transformer Balanced 4-Wire 2-Wire E&M Signaling
E&M Signaling
Types 1 to 5 (user-selectable)
Audio Input Level
-20 to +10 dBm for 0 dBm0, in 1 dB steps
Audio Output Level
-20 to +10 dBm for 0 dBm0, in 1 dB steps
Filtering
300 to 3400 Hz Input and Output
Mechanical
RJ11
Pin #
Name
1
+TX
2
-TX
3
+RX
4
-RX
5
E
6
M
With Protection
Switch Jumper on
Data
With Protection
Switch Jumper on
ADPCM
Signal Function
Pin #
Name
Name
SIGNAL GROUND
1, 19, 20, 27
SG
SEND DATA
4
22
SD-A
SD-B
SEND TIMING
5
23
ST-A
ST-B
RECEIVE DATA
6
24
RD-A
RD-B
REQUEST TO SEND
7
25
RS-A
(see Note below)
RS-B
(see Note below)
-TX
+TX
RECEIVER TIMING
8
26
RT-A
RT-B
CLEAR TO SEND
9
27
CS-A
(see Note below)
CS-B
(see Note below)
DATA MODE
11
29
DM-A
DM-B
-RX
+RX
RECEIVER READY
13
31
RR-A
RR-B
E
M
TERMINAL TIMING
17
35
TT-A
TT-B
MOD FAULT
3
-
DEMOD FAULT
21
-
MASTER CLOCK
16
34
MC-A
MC-B
Note: The Request to Send and Clear to Send lines are jumpered together on the
Demodulator/M&C card (AS/4973), since the modem does not support polled
operation.