Installation

MINIMAC Rack Management System

2–18

Rev. 0

2.4.5

COMM 7 Installation

The COMM 7 Rack is identified as the SDM-658 Modem Rack (Figure 2-9). Install the
equipment as follows:

1.

Modem M&C Boards – Set Switch Pack #1 as follows:

Command

Response

Set Baud Rate

9600 bit/s

Set Parity

EVEN

2. Set jumpers as follows:

Command

Response

Set Remote Operation

485

2.

Install an SDM-308-4 Data Modem into the first rack slot. The modem should be
identified as the Backup #1. Set Switch Pack #2 ( M&C Board) Remote Address
to 9.

3.

Install an SDM-308-5 Data Modem into the second rack slot. The modem should
be identified as the Backup #2. Set Switch Pack #2 ( M&C Board) Remote
Address to 10.

4. Install an SMS-658 Switch into the third rack slot. (This unit will permit

switching from Primary to Backup units.) Set the following:

Command

Response

Set Remote Address

11

Set Baud Rate

9600 bit/s

Set Parity

EVEN

Set Remote Operation

RS-485 (2-wire)

5. Install an SDM-308-4 Data Modem into the fourth rack slot. The modem should

be identified as Primary #1. Set Switch Pack #2 Remote Address to 1.

6. Install an SDM-308-5 Data Modem into the fifth rack slot. The modem should be

identified as Primary #2. Set Switch Pack #2 Remote Address to 2.

7. Attach a ribbon cable (customer-furnished) to the REMOTE port of each data

modem and the switch. Connect a customer-fabricated cable from the switch to
the MiniMAC port expander in the COMM 7 position.