Comm 7 installation, 5 comm 7 installation – Comtech EF Data MiniMac Installation ManualOperation Manual Operation Manual User Manual
Page 120
Installation
MINIMAC Rack Management System
2–18
Rev. 0
2.4.5
COMM 7 Installation
The COMM 7 Rack is identified as the SDM-658 Modem Rack (Figure 2-9). Install the
equipment as follows:
1.
Modem M&C Boards – Set Switch Pack #1 as follows:
Command
Response
Set Baud Rate
9600 bit/s
Set Parity
EVEN
2. Set jumpers as follows:
Command
Response
Set Remote Operation
485
2.
Install an SDM-308-4 Data Modem into the first rack slot. The modem should be
identified as the Backup #1. Set Switch Pack #2 ( M&C Board) Remote Address
to 9.
3.
Install an SDM-308-5 Data Modem into the second rack slot. The modem should
be identified as the Backup #2. Set Switch Pack #2 ( M&C Board) Remote
Address to 10.
4. Install an SMS-658 Switch into the third rack slot. (This unit will permit
switching from Primary to Backup units.) Set the following:
Command
Response
Set Remote Address
11
Set Baud Rate
9600 bit/s
Set Parity
EVEN
Set Remote Operation
RS-485 (2-wire)
5. Install an SDM-308-4 Data Modem into the fourth rack slot. The modem should
be identified as Primary #1. Set Switch Pack #2 Remote Address to 1.
6. Install an SDM-308-5 Data Modem into the fifth rack slot. The modem should be
identified as Primary #2. Set Switch Pack #2 Remote Address to 2.
7. Attach a ribbon cable (customer-furnished) to the REMOTE port of each data
modem and the switch. Connect a customer-fabricated cable from the switch to
the MiniMAC port expander in the COMM 7 position.