MINIMAC Rack Management System
Installation
Rev. 0
2–13
2.4.1
COMM 3 Installation
The COMM 3 rack is identified as the V2200 Dual Converters. Install the converters as
follows (Figure 2-9):
1.
Go to the Utility System Menu, set all converters as follows:
•
Baud Rate: 9600 bit/s
•
Parity: Even
•
Remote: RS-485 (2-wire operation)
2.
Install a V2200 Dual Converter into the first rack slot. The converter should be
identified as the Up Converter.
•
Side A will be Address 1
•
Side B will be Address 2
3.
Install a V2200 Dual Converter into the second rack slot. The converter should
be identified as the Down Converter.
•
Side A will be Address 3
•
Side B will be Address 4
4.
Install a V2200 Dual Converter into the third rack slot. The converter should be
identified as the Dual Converter.
•
Side A will be Address 5
•
Side B will be Address 6
5.
Attach a ribbon cable (customer-furnished) to the REMOTE port of each
converter. Connect the ribbon cable to a customer-fabricated cable (Figure 2-5)
then to the MiniMAC port expander in the COMM 3 position.