MINIMAC Rack Management System

Installation

Rev. 0

2–17

2.4.4

COMM 6 Installation

The COMM 6 Rack is identified as the SDM-8000 Modem Rack (Figure 2-9). Install the
equipment as follows:

1.

Install an SDM-8000 Modem into the first rack slot. The modem should be
identified as the Backup #1. Set Remote Address at 9. Set all modems as follows:

Command

Response

Go to

Utility System Menu

Set Baud Rate

9600 bit/s

Set Parity

EVEN

2. SDM-8000 M&C Board Only – Set jumpers as follows:

Command

Response

Remote

485

2/4 wire

2-wire

Note: The SDM-300 Modem shall have a 50-pin overhead data interface
connector at the J8 port. Any other connector will not mate with the
SMS-7000 switch.

4.

Install an SDM-300 Modem into the second rack slot. The modem should be
identified as Backup #2. Set the Remote Address to 10.

5.

Install an SMS-7000 Switch into the third rack slot. (This unit will permit
switching from Primary to Backup units.) Set the following:

Command

Response

Set Remote Address

11

Set Baud Rate

9600 bit/s

Set Parity

EVEN

Set Remote Operation

RS-485 (2-wire)

6.

Install an SDM-8000 Modem into the fourth rack slot. The modem should be
identified as Primary #1. Set the Remote Address to 1.

7.

Install an SDM-300 Modem into the fifth rack slot. The modem should be
identified as Primary #2. Set Remote Address to 2.

8.

Attach a ribbon cable to the REMOTE port of each modem and the switch
(Modem Control). Connect a customer-fabricated cable (Figure 2-5) from the
SMS-7000 Switch USER PREMOTE to the MiniMAC port expander in the
COMM 6 position.