Installation

MINIMAC Rack Management System

2–16

Rev. 0

2.4.3

COMM 5 Installation

The COMM 5 Rack is identified as the CST-5000 Rack (Figure 2-9). Install the
equipment as follows:

Note: The RFT-500 Redundancy System is an outside installation. Refer to the
Installation and Operation Manual for the proper procedures.

1.

Install the RFT-500 Redundancy System.

Set RFT A to Address 2.

Set RFT B to Address 3.

2.

Install an RSU-503L Switch. Set the switch as follows:

Command

Response

Set Baud Rate

9600 bit/s

Set Remote Address

1

Set Parity

EVEN

Set Remote Operation

RS-485 (2-wire)

3.

Attach a customer-fabricated cable to the REMOTE port (J16) of the RSU
Switch. Connect the 9-pin end to the MiniMAC port expander in the COMM 5
position.