Installation

MINIMAC Rack Management System

2–14

Rev. 0

2.4.2

COMM 4 Installation

Note: Adaptive Broadband model numbers are shown as the basic number, such as
SDC-600. Installation of SDC-600A units can replace the older units.

The COMM 4 rack is identified as the C-Band Converters (Figure 2-9). Install the backup
converters adjacent to the switch.

1. Set all converters as follows:

Command

Response

Go to

Utility System Menu

Set Baud Rate

9600 bit/s

Set Parity

EVEN

Set Remote Operation

RS-485 (2-wire)

2. Install an SDC-600 Converter into the first rack slot. The converter should be

identified as the Up Converter, Primary #1. Set the Remote Address to 1.

3. Install an SDC-600 Converter into the second rack slot. The converter should be

identified as the Up Converter, Backup #1. Set the Remote Address to 9.

4. Install an SCS-500 switch into the third rack slot. (This unit will permit switching

from Primary to Backup units.)

5. Install an SDC-400 Converter into the fourth rack slot. The converter should be

identified as the Down Converter, Backup #2. Set the Remote Address to 10.

6. Install an SDC-400 Converter into the fifth rack slot. The converter should be

identified as the Down Converter, Primary #2. Set the Remote Address to 2.

7. Attach a ribbon cable to the REMOTE port of each converter. Connect the ribbon

cable to a customer-fabricated cable (Figure 2-5) then to the MiniMAC port
expander in the COMM 4 position.