beautypg.com

Comtech EF Data CDD-880 User Manual

Page 96

background image

CDD-880 Multi Receiver Router

Revision 1

Ethernet-based Remote Product Management

MN-CDD880

5–36

Input Port Status

From left to right: 

Column

Description

Demod #

This is the available ”filled” demodulator slot (automatically
assigned in pairs per each installed dual demodulator card).

Lock

Displays the status of the VersaFEC decoder as Locked or
Unlocked.

Eb/No (dB)

Estimated channel noise level.

Estimated Corrected BER

Bit Error Rate after VersaFEC decoding.

RSSI (dB)

Relative Signal Strength Indicator (0 – 60 dB of demod operating
range).

Rx Freq Offset (Hz)

Estimated offset from demod configured frequency (in Hz).

Circuit ID

Displays the identification label assigned to the individual
demodulator.

Events

Each event or alarm is logged with a Date‐ and Time‐stamp, and a Description is provided. The 
state  of  the  ‘STORED  EVENT’  LED  provided  on  the  unit  front  panel  and  on  the  Web  Server 
Interface  Virtual  Front  Panel  lights    amber  to  indicate  the  presence  of  any  stored  event(s)  or 
alarm(s).   
 
Click [Clear Event Table] to delete all existing logged entries from the Events log. The log is then 
reset  to  one  (1)  entry:  “INFO  –  Event  Log  Cleared”.  The  state  of  the  ‘STORED  EVENT’  LED 
provided on the unit front panel and on the Web Server Interface Virtual Front Panel remains 
unlit in the absence of any stored event(s) or alarm(s).