5–24

CDM‐840  Remote  Router  Installation  and  Operation  Manual  (CEFD  P/N 
MN‐CDM840) 

 

Current Es/No (read‐only) –This is the current Es/No of the demod, in 0.1 dB increments. 

The displayed range is from ‐5 dB to 35 dB. 
 

Current Rx MODCOD (read‐only) – This is the current MODCOD of the demod. It is used to 

measure the Current Es/No. 

Rx ACM Events (read-only)

In  addition  to  the  date‐  and  time‐stamp  assigned  for  each  event,  information  is  presented  as 
follows (from left to right):  
 

Column

Description

Demod #

This is the available "FILLED" demodulator slot (automatically assigned
in pairs per each installed dual demodulator card).

New ES/No

This is the Es/No reported by the receiving demod when the MODCOD
switch occurred.

New Rx ModCod

This is the MODCOD that the demod was switched to by the ACM
algorithm.

New Rx Data Rate

This is the Rx Data Rate at the time of this event.

 
Click [Clear ACM Events] to clear all ACM statistics from the buffer.