CDD-880 Multi Receiver Router

Revision 1

Ethernet-based Remote Product Management

MN-CDD880

5–22

Rx Spectrum Invert – Use the drop‐down menu to select Spectrum Inversion operation as 

either Normal or Inverted
 

Rx Descram – Use the drop‐down menu to select Rx Descrambling as either Off or Normal

 

Eb/No  Alarm  Pt  (0.1‐16.0)  –  Enter  the  Eb/No  Alarm  Point  value,  in  dB.  This  value,  as 

calculated  by  the  demodulator,  is  the  energy  per  bit  (Eb)  divided  by  the  noise  spectral 
density (No).  

 

 

When  ACM  is  enabled,  the  CDD‐880  will  issue  an  alarm  only  if  the 
demodulator is at the lowest available MODCOD (BPSK). 
 

Circuit ID (4‐24) – Enter an identification label for the demod, from four to 24 characters. 

Click [Submit] to save. 
 

Acquisition Range (1‐200) – Enter the Acquisition Range value, in kHz. Note that the range is 

dependent on the current symbol rate of the demodulator. Click [Submit] to save.