Compuprint 9058 Programmer Manual User Manual
Page 86
COMPUPRINT Mode
A78408098-003
84
2 of 5 Matrix
DC4 DC4 ESC ! n 19 p EM
The 2/5 MATRIX bar code. Data format length is
variable and the supported character set only
provides ASCII numeric figures 0 to 9. N indicates
the bar code height in units of 1/6 inch and must be
in the range 1 to 12. The parameter p must be NUL
(hex. 00) if no Human Readable Characters are to
be printed, and 1 (hex. 01) if they are to be printed.
Code 39
DC4 DC4 ESC ! n 20 p EM
The CODE 39 bar code. Data format length is
variable and must always start and end with an
asterisk. It can contain the alphanumeric character
listed below:
0 1 2 3 4 5 6 7 8 9
A B C D E F G H I J K L M N O P Q R S T U V W X
Y Z -. SPACE $ / + % * ( as start / stop
character)
The parameter indicates the bar code height in
units of 1/6 inch and must be in the range 1 to 12.
The p parameter must be NUL (hex. 00) if no
Human Readable Characters are to be printed, and
1 (hex. 01) if they are to be printed.