Compuprint 9058 Programmer Manual User Manual
Page 78
COMPUPRINT Mode
A78408098-003
76
UPC-EAN 5
DC4 DC4 ESC ! n 6 p EM
ADD ON-5 bar code data fields contain numeric
data only: question marks will be printed in place of
HRC string otherwise, if possible.
If 6-digit strings will be received within a DC4 DC4
ESC (... EM control sequence and o check-digit
option field is missing or takes NULL value, the
symbol will encode the first 5 digits and the 6
th
received digit will be used as check digit, even
though this may affect its readability; if o check
digit option takes 1 value, the 6
th
digit is matched
versus the internally generated check-digit an
question marks will printed in place of HRC string
when mismatching, if possible.
If 5-digit strings will be received and o check digit
field is missing or takes NULL value, question
marks will be printed in place of HRC string, if
possible; if o field takes value 1, the check digit will
be computed applying the internally available
algorithm to the received string in order to properly
encode the symbol.
If f field is missing or takes value 1, the 5-digits
HRC string will be printed above the Bar/Spaces
symbol and its height will be part of the overall
symbol’s height; the check-digit will never show on
HRC string. If f field takes value 0, the symbol’s
encoding will print at full height.