Troubleshooting
Error message
Cause
Correction
Error 09:
Cross transport cannot
leave the switch
During the initialization motion after
switch-on, the cross transport has
reached ES01 but cannot move away
from this switch (direction is not
reversed) –
Using the test program „CT motor
actuation“, enter slower speed so that
CT motor runs and reverse direction
using arrow keys; if motor fails to
reverse direction: Check connection
between 9020020 and power unit
(connector); check BERGER power unit;
if motor reverses direction, check limit
switch ES01.
Cross transport scan
photocell 14
While moving from the A machine to the
B machine, the photocell 14 failed to
detect the sewing piece properly
Check photocell and film; check
programmed distances; Check LED 5 at
I/O module 9020013; this LED indicates
the status of photocell 14.
B head error
post-sewing with F2
Failure at B machine
The sewing of a seing piece in the B
machine cannot be finished; continue
sewing manually
B head runs too long
Time-out at photocell 13 (does not light
during sewing after 10 seconds)
Failure during sewing process; possibly
a sewing piece blocks the transport or
conceals the reflective film
A head thread breakage
A machine thread monitor responds
Pass thread through needle; change
sensitivity in GP 22;23.
B head thread breakage
B machine thread monitor responds
Pass thread through needle
Error 48:
I/O RES
Internal hardware failure during data
transmission
Replace adapter PCB 9020013 –
9020020