Location requirements – Beisler 1360-4 User Manual
Page 45

C-5
Service Instructions Automatic Multi-Head Serging Machine1365-4
Beisler GmbH
C.2
Location requirements
C.2.4 Supply connections
The machine requires on-site power supply cables with a minimal
cross-section of 1.5 mm and a connection to a compressed-air supply
system.
Power connection:
The power supply of the machine requires a properly grounded power
connection with:
Grounding plug
230 V ± 10 %, 50/60 Hz
Fusing
16 A
NOTE - Peak voltages!
The correct function of the machine requires that the po-
wer system supplies a constant current. Peak voltages
may particularly impair the stability of the program con-
trol.
Compressed-air supply:
The on-site compressed-air supply system must meet the following re-
quirements:
Operating pressure
6 bar
Compressed-air quality
oil-free
Compressed-air consumption
40 NL/AT