Functions of the machine – Beisler 1360-4 User Manual
Page 24

Operating Instructions Automatic Multi-Head Serging Machine 1365-4
Beisler GmbH
B-14
B.2
Functions of the machine
B.2.8 Switches
Power switch / Emergency stop switch, Fig. 15:
Main switch / Emergency stop switch
The main switch 2 is used to switch the power supply of the machi-
ne on or off. In case of extended production intermissions, the machi-
ne must be switched off with the main switch so that all functional units
are disabled. The main switch is located at the ma-
chine frame below the A machine and is also used
as an emergency stop switch.
On/off switch for the bonding station heating module
The heating module 1 of the bonding station has
a thermostat with a separate on/off switch that is in-
stalled below the bonding station.
Program stop switch
When the program stop switch 3 is pressed, all
machine movements and the sewing process are in-
terrupted immediately.
The switch is locked after it has been pressed. When
rotated clockwise, the switch is unlocked and returns
to its original position. The control performs a reset.
NOTE - Program stop switch!
When the program stop switch is actuated, it merely can-
cels the machine cycle while the program control and
the machine drive continue to be supplied with electric
voltage. To interrupt the power supply, switch the ma-
chine off using the main switch.
A
C
B
Fig. 15