beautypg.com

Avery Dennison 6035 Programmer Manual Rev.CA 6/01 User Manual

Page 207

background image

7-16 Programmer’s Manual

Parameters

drive

The letter of the drive to make available.

options…

Any of the following options. In most environments,
you can use the defaults for each option.

/Bnnnn

Specifies to use baud rate nnnn.

Values for nnnn are: 300, 1200, 2300,

4800, 9600, 19200, 38400, 57600, and

115k . The default is 115k.

+

Specifies to use packet transmissions.

If you do not specify this option, the

default depends on the baud rate. For

baud rates over 19200, REMDISK uses

packet transmissions. For baud rates

at or below 19200, REMDISK uses

non-packet transmissions.

/COM1

Specifies to use the COM1 serial

communications port.

/S

Specifies to run REMSERV silently

without any screen output.

/Tnnnn

Specifies nnnn as the time-out in

seconds. Values are 3-3640.

/?

Displays a short help screen

Help Screen Notes

Note the following help screen discrepancies that appear if you
use the /? option:

The /n before the example should not appear.

The /H option appears on the screen, but is non-functional.
Do not use it.

You can press any key to exit REMSERV, not only b.