5-2 Programmer’s Manual

C O D A B A R I N F O

SCAN1223.LIB only. The CODABARINFO data structure
contains 1223 scanner configuration information about Codabar
bar codes. To read these values, applications call
scnGetCodabarInfo; to set these values, they call
scnSetCodabarInfo.

typedef struct _CodabarInfo

{

unsigned char uchEnable;

unsigned char uchLength1;

unsigned char uchLength2;

unsigned char uchEnableCLSIEdit;

unsigned char uchEnableNOTISEdit;

} CODABARINFO;

Field

Description

uchEnable

Enable/disable the ability to scan Codabar
bar codes.
Default: SCN_DISABLE

uchLength1
uchLength2

Specifies lengths (including start and stop
characters) for Codabar bar codes. You
can specify one or two lengths, a range of
lengths, or that any length is valid. Enter
values as follows:

Option

uchLength1 uchLength2

1 Length

Value

0

2 Lengths Higher Value Lower Value
Range

Min. Value

Max. Value

Any length 0

0

Default: 5 (uchLength1) and 55
(uchLength2)