5-10 Programmer’s Manual

Field

Description

uchSameSymbolTMO

The minimum time that must elapse
between scans of the same bar code (in
increments of .1 seconds). You must set
uchTriggerMode to 1 when setting this
parameter. Values are 1-99.
Default: 10

uchLinearCodeSecur

The scan security level for linear bar
codes. Values are 1-4. Select a higher
level for lower quality bar codes. See
“Scan Security Levels ” for more
information.
Default: 1

uchBiDirRedun

Enable/disable the requirement to scan
bar codes in both directions (forward and
reverse).
Default: SCN_DISABLE


Scan Security Levels

The following table describes the security levels used with the
uchLinearCodeSecur parameter.

Level Number Description

1

The following bar code types (provided they meet
the specified length requirements) must be
scanned successfully twice:

Codabar

Any length

MSI

4 characters or less

D 2 of 5

8 characters or less

I 2 of 5

8 characters or less

2

All bar code types of all lengths must be scanned
successfully twice.