Avery Dennison 6035 Programmer Manual Rev.CA 6/01 User Manual
Page 165
5-6 Programmer’s Manual
Field
Description
uchEnableC32Prefix
Enable/disable the ability to add “A” as a
prefix to all Code 32 bar codes. You must
enable uchCvtC39toC32 when enabling
this parameter.
Default: SCN_DISABLE
uchLength1
uchLength2
Specifies lengths (including check digits)
for Code 39 bar codes. You can specify
one or two lengths, a range of lengths, or
that any length is valid. If
uchEnableFullASCII is enabled, a range or
any length is preferred. Enter values as
follows:
Option
uchLength1 uchLength2
1 Length
Value
0
2 Lengths
High Value Low Value
Range
Min. Value
Max. Value
Any length
0
0
Default: 2 (uchLength1) and 55
(uchLength2)
uchVerifyCheckDigit
Enable/disable the ability to check the
integrity of Code 39 bar codes. When this
parameter is enabled, only Code 39
symbols with a modulo 43 check digit are
decoded.
Default: SCN_DISABLE
uchXmitCheckDigit
Enable/disable the ability to transmit check
digits with the data.
Default: SCN_DISABLE
uchEnableFullASCII
Enable/disable the ability to scan Full
ASCII Code 39 bar codes. The scanner
cannot distinguish Code 39 bar codes from
Full ASCII Code 39 bar codes. Do not
enable uchEnableTrioptic and
uchEnableFullASCII at the same time.
Default: SCN_DISABLE