Avery Dennison 6035 Programmer Manual Rev.CA 6/01 User Manual
Page 185

5-26 Programmer’s Manual
Field
Description
uchCvtEAN8toEAN13
Enable/disable the ability to convert 
EAN8 zero-extended bar codes to 
EAN13 format. You must enable 
uchEAN8ZeroExtend when enabling this 
parameter. 
Default: SCN_ENABLE 
uchSecurityLevel
The scan security level for UPC/EAN 
bar codes. See “Scan Security Levels ” 
for descriptions of each level. Values 
are 0-3. 
Default: 0 
uchEnableCouponCode
Enable/disable the ability to scan UPCA, 
UPCA+2, UPCA+5, and UPC/EAN128 
bar codes. You must set 
uc hEnableSupps  to 2 when enabling this 
parameter. 
Default: SCN_DISABLE 
 
Scan Security Levels 
The security level specifies how aggressive the scanner works 
during a scan. With a low bar code quality, the scanner must 
work more aggressively, and vice versa. Choose the minimum 
security level you need, according to the following guidelines: 
L e v e l Description
0
Provides security sufficient for bar codes that meet 
specifications. 
1
Provides security sufficient for bad scans that are limited 
to characters 1, 2, 7, and 8. 
2
Provides security sufficient for bad scans that are not 
limited to characters 1, 2, 7, and 8. 
3
Provides security for continued bad scans after you 
increase security to level 2. 
You may need to adjust the security as needed during scanning.
