beautypg.com

AMETEK 2003RP User Manual

Page 98

background image

[SOURce:]FREQuency

This command sets the frequency of the output sinewave.

Command Syntax

[SOURce:]FREQuency

Parameters

range specified by the LIM:FREQ:LOW and LIM:FREQ:HIGH
commands

Unit

Hz (Hertz)

*RST Value

defined by PON

Examples

FREQ 50

Query Syntax

FREQuency?

Returned Parameters

Related Commands

LIM:FREQ;LOW? LIM:FREQ:HIGH?

[SOURce:]VOLTage

This command programs the AC rms output voltage level of the power source. The
maximum voltage value allowed is determined by the selected voltage range. For 2003RP-
AV models configured for single voltage range, only one range is available.

Command Syntax

[SOURce:]VOLTage[:LEVel]

Parameters

0 to maximum voltage range specified by the VRAN command

Unit

V (rms voltage)

*RST Value

0 volt

Examples

VOLT 250

VOLT:LEV 25

Query Syntax

[SOURce:]VOLTage[:LEVel]?

Returned Parameters

Related Commands

VOLT:RANGe