AMETEK 2003RP User Manual
Page 102

Example: Individual Phase Loss Test
The following command sequence will drop the output of phase A only for 10 cycles at 400
Hz.
/* Set up sequence
VOLT 115;FREQ 400
Set output voltage to 115 V at 400 Hz (all phases)
INST:COUP 0
Uncouple output phases
INST:NSEL 1
Select phase A
OUTP 1
Close output relay
OUTP:STAR:STAT 1
Enable start phase mode
OUTP:STAR:PHAS 90
Set start phase angle to 90 degrees on phase A
OUTP:DROP 0.025
Drop for 25 ms (10 cycles @ 400 Hz)
Output drop status query
The status of a drop in progress can be queried using the query format of the OUTP:DROP
command. This query will return a
(0) or the drop is still in progress (1).
Command Syntax
OUTPut:DROP
Parameters
*RST Value
none
Examples
OUTP:DROP 0.001
Query Syntax
OUTP:DROP?
Returned Parameters
0 | 1
Related Commands
OUTP:STAR:STAT
OUTP:STAR:PHAS
INST:COUP
INST:NSEL
- CW-M (48 pages)
- CW-M Corrected Table 4-2 in (1 page)
- CW-P (62 pages)
- Lx Series (205 pages)
- CW Series Programming Manual (25 pages)
- Ls Series II Programming Manual (242 pages)
- Compact i/iX Series (157 pages)
- Compact IX 2253 (157 pages)
- Compact i/iX Series Software Manual (203 pages)
- ASD Series Quick Start (5 pages)
- ASD Series (120 pages)
- i-iX Series II Programming Manual (226 pages)
- DLM 600W Series Programming Manual (24 pages)
- M131 Programming Manual (99 pages)
- DLM Series (74 pages)
- DLM 600W Series (82 pages)
- BPS Series (153 pages)
- DLM600 Series (16 pages)
- DCS-E 1.2kW Series (65 pages)
- DLM-E 4kW Series Programming Manual (32 pages)
- M136 (8 pages)
- DCS-E 3kW Series (94 pages)
- CTS 3.0 (166 pages)
- CSW Series (174 pages)
- 2001RP (131 pages)
- MX CTSH (151 pages)
- MXCTSL Administrator Manual (27 pages)
- MX CTSL (157 pages)
- RS Series (228 pages)
- MX Series Installation Manual (35 pages)
- Ls AC source (2 pages)
- MX15 Series (184 pages)
- Ls Series II (226 pages)
- Lx Series Driver Manual (275 pages)
- MX Series Rev: AY (257 pages)
- iX Series (341 pages)
- i-iX Series II (258 pages)
- GUPS 2400A-108 (36 pages)
- HPD Series (58 pages)
- HPD Series Operation Manual (41 pages)
- HPD Series GPIB-Multichannel (134 pages)
- PLA-PLW Programming Manual (74 pages)
- ReFlex Mating Connnectors for Controller (3 pages)
- LPDC-16V (4 pages)