beautypg.com

2specifications – AMETEK 2003RP User Manual

Page 12

background image

2

Specifications

All specifications at 25 5 C and 400 Hz output unless noted otherwise.

2.1 Electrical

Input

Parameter

Specification

Line Voltage:

107/120 V

AC

± 10%

208/230 V

AC

± 10%

Line Current:

35 A

RMS

maximum, line voltage = 96 V

AC

, full-load,

PF = 0.6, Efficiency = 75%, (typical)

Inrush Current:

185 A

PK

at 253 V

AC

input line

Input power factor:

0.6 at full-load and 120 V

AC

input

Line Frequency

1

:

50/60 Hz ± 5%

Efficiency:

75% typical (depending on line and load)

Hold-Up Time:

10 ms (with no effect on output)

Isolation Voltage:

1350 V

AC

, input to chassis

2300 V

AC

, input to output


Output

Parameter

Specification

Outputs

Phases:

3

Mode:

AC

Coupling:

AC

Voltage

2003RP:

0 to 135 V or 0 to 270 V

(see Section 3.7)

2003RP-AV:

0 to 115 V or 0 to 230 V
or
0 to 115 V only (factory set)

2003RP-HV:

0 to 156 V or 0 to 312 V

(see Section 3.7)

Resolution:

0.1 volt

Accuracy

1

:

± 0.1% of full scale, 16 Hz - 100 Hz
± 0.2% of full scale, 100 Hz - 2000 Hz
Applies from 10 to 100% of voltage range.

1

Supplementary specification applies outside indicated frequency ranges.