beautypg.com

AMETEK 2003RP User Manual

Page 26

background image

3.3.2 High Input Voltage Range Configuration (208/230 V)

In order to change the voltage range configuration:

1. Turn off the input circuit breaker.

2. Disconnect AC input power at TB1.

3. Remove the AC Power Source top cover by removing (17) #6-

32 x 5/16” FLH screws.

There are a total of 7 screws on the sides and 10 screws on the top that hold the cover.

4. The high input voltage range is set by removing the wire from A4-E2 and connect to

CR1-AC2.

Figure 3-4: Internal Jumper Location, Input Line Voltage 208/230