Parameter

Specification

Load Regulation

1

:

± 0.1% of full scale, 16 Hz - 500 Hz

External Sense:

Will compensate for up to 7% of voltage drop up to 2
kHz

Line Regulation:

± 0.02% of full scale

Settling time:

From start of voltage change from 5.0 V

RMS

or

higher voltage to within 2% of final value:

No load:

16 ms

Full load:

300 ms

(16 ms to within 15% of final value)

Distortion (THD
into linear load):

0.5% typical, 1.0% maximum below 100 Hz
1.0% typical, 2.0% maximum 100 Hz - 2000 Hz

DC Offset voltage:

AC coupled transformer output

Output noise:

< 0.1 V

RMS

typical

( 20 kHz to 1 MHz at full load )

Temperature
coefficient:

± 0.02% of full scale per degree C

Stability:
(24 hours)

± 0.015% of full scale under constant load, line and
temperature

Total Power:

2000 VA maximum at full scale voltage, either range

Current per Output Phase

2003RP:

2003RP-AV:

2003RP-HV

Volt Range

135
270

115
230

156
312

A

RMS

5.0
2.5

5.9
2.9

4.3
2.1

A

PEAK

15.0

7.5

17.6

8.8

12.9

6.3

Adjustable Limit:

0.0 to Maximum available RMS current for selected
voltage range. Maximum current is available for
output voltage from 50% to 100% of range. Current
derates below 50% of range setting. See derating
chart.