beautypg.com

AMETEK 2003RP User Manual

Page 112

background image

10.10.6

*RST

This command resets the AC source to a setting defined by the values in the register defined
by PON if valid or by the following factory-defined states:

Table 10-4: *RST Default Parameter Values

Item

Value

Item

Value

VOLT

5.0 V

FREQ

60 Hz

CURR

5.0 A

VOLT:RANGe:LEVel

135 V

VOLT:RANGe:AUTO

0 (OFF)

OUTP

0 (OFF)

DISP:MODE

1 (FREQ)

OUTP:STARt:STATe

0 (OFF)

OUTP:STARt:PHASe

0

NOTE: The factory defaults cannot be used on units with the -AV option. Instead, one

of the setup registers 0 through 7 must be selected for the power on state.
Executing the *RST command will recall the settings from the assigned setup
register. Use the SYST:PON to select one of the available setup registers for
the power on and *RST states.

Command Syntax

*RST

Parameters

None

Related Commands

*SAV

Table 10-5: Status Registers - Power on Conditions

Register

Status on Power On

Status after *RST

- ESE register

All 0‟s

All 0‟s

- ESR register

PON bit = 1, all others 0

PON = 0, all others unaffected

- STB register

All 0‟s

All 0‟s

- SRE register

All 0‟s

All 0‟s

Note: Sending the *RST command will cause the unit to recall the REMOTE or LOCAL state
based on the setting of the SYSTem:KLOCk command. This may put the unit in local if this
state is set to 0. To avoid this, either set the SYSTem:KLOCk state to 1 or follow the *RST
command with a SYST:REM command. See SYSTem:KLOCk for information on the power
up remote / local state.