beautypg.com

AMETEK 2003RP User Manual

Page 113

background image

10.10.7

*SAV

This command stores the present state of the AC source to a specified location in memory.
The RP Series offers eight non-volatile memory locations for storing instrument setups.

Command Syntax

*SAV

Parameters

0 through 7

Related Commands

*RCL

*RST

10.10.8

*SRE

This command sets the condition of the Service Request Enable Register. This register
determines which bits from the Status Byte Register (see *STB for its bit configuration) are
allowed to set the Master Status Summary (MSS). A “1” in any Service Request Enable
Register bit position enables the corresponding Status Byte Register bit and all such enabled
bits then are logically OR-ed to cause Bit 6 of the Status Byte Register to be set. See
Section 12 for more details concerning this process.

When the controller conducts a STB? command, the MSS bit is not cleared. When *SRE is
cleared (by programming it with 0), the source cannot generate an MSS bit.

Command Syntax

*SRE

Parameters

0 to 255

Default Value

128

Example

*SRE 255

Query Syntax

*SRE?

Returned Parameters

(Register binary value)

Related Commands

*ESE *ESR

10.10.9

*STB?

This query reads the Status Byte register, which contains the status summary bits and the
Output Queue MAV bit. Reading the Status Byte register does not clear it. The input
summary bits are cleared when the appropriate event registers are read (see Section 12 for
more information).

Table 10-6: Bit Configuration of Status Byte Register

Bit Position

7

6

5

4

3

2 - 0

Bit Name

OPER

MSS

ESB

MAV

QUES

not used

Bit Weight

128

64

32

16

8

OPER

operation status summary

MSS

master status summary

ESB

event status byte summary

QUES

questionable status summary

MAV

message available

Query Syntax

*STB?

Returned Parameters

(Register binary value)