beautypg.com

AMETEK 2003RP User Manual

Page 109

background image

10.10.1

*CLS

This command clears the following registers (see chapter 12 for descriptions of all status
registers):

Standard Event Status

Status Byte

Error Queue

Command Syntax

*CLS

Parameters

None

10.10.2

*ESE

This command programs the Standard Event Status Enable register bits. The programming
determines which events of the Standard Event Status Event register (see *ESR?) are
allowed to set the ESB (Event Summary Bit) of the Status Byte register. A "1" in the bit
position enables the corresponding event. All of the enabled events of the Standard Event
Status Enable Register are logically OR-ed to cause the Event Summary Bit (ESB) of the
Status Byte Register to be set. See Section 16 for descriptions of the Standard Event Status
registers.

The query reads the Standard Event Status Enable register.

Table 10-2: Bit Configuration of Standard Event Status Enable Register

Bit Position

7

6

5

4

3

2

1

0

Bit Name

PON

not used

CME

EXE

DDE

QYE

not used

not used

Bit Weight

128

32

16

8

4

CME

Command error

DDE

Device-dependent error

EXE

Execution error

QYE

Query error

PON

Power-on

Command Syntax

*ESE

Parameters

0 - 255

Power-On Value

128

Example

*ESE 129

Query Syntax

*ESE?

Returned Parameters

(Register value)

Related Commands

*ESR? *STB?