beautypg.com

Led indications – D-Link KX-TDA100 User Manual

Page 96

background image

2.4 Installation of the Trunk Cards

96

Installation Manual

BNC (coaxial) Connector (RX)

LED Indications

No.

Signal Name

Level [V]

Function

1

RX-

(-)

Receive data (-)

2

RX+

(+)

Receive data (+)

Indication

Colour

Description

CARD STATUS

Green/Red

Card status indication

OFF: Power Off

Green ON: Normal (all ports are idle)

Green Flashing (60 times per minute): Normal (a port is in use)

Red ON: Fault (includes reset)

Red Flashing (60 times per minute): Out of Service

SYNC-ERR

Red

Non-synchronisation status indication

OFF: Normal

ON: Out of synchronisation

RAI

Red

RAI signal status indication

OFF: Normal

ON: Alarm (Clock Slave)

Flashing (60 times per minute): Alarm (Clock Master)

AIS

Red

AIS status indication

OFF: Normal

ON: Alarm

SYNC

Green

Synchronisation status indication

OFF: Not synchronised

ON: Synchronised

Flashing (60 times per minute): Synchronised (Clock Master)

D-LINK

Green

Data link status indication

OFF: Not established

ON: Established

1

2