beautypg.com

D-Link KX-TDA100 User Manual

Page 35

background image

1.4 Specifications

Installation Manual

35

PSU Capability

Each PSU supports a different amount of load figures.

Calculation Example (KX-TDA200)

The total load figure is 96. As this is between 64 and 128, you should install the PSU-M. But if you expect
expansion in the future, it may be better to install the PSU-L. There is no harm in installing a PSU that is
larger than is required for the current configuration.

CS (1 unit)

4

PT-interface CS (1 unit)

4

ISDN Extension

2

VPS (1 port)

1

*1

Only the extension cards that can support SLTs count for the load figures.

PSU Type

Maximum Load Figures

PSU-S

*1

*1

Available for the KX-TDA100

64

PSU-M

*2

*2

Available for the KX-TDA100 and KX-TDA200

128

PSU-L

*3

*3

Available for the KX-TDA200

512

Equipment Type

Load Figure

KX-T7600 series DPT

48 units

48

Other DPT

2 units

8

SLC16

1 card

16

MSLC16

1 card

16

VPS

8 ports

8

Total

96

Equipment Type

Load Figure