List of errors and solutions – D-Link KX-TDA100 User Manual
Page 231
4.1 Troubleshooting
Installation Manual
231
List of Errors and Solutions
The tables below list the errors and their solutions.
When an error whose error code is indicated with "*" occurs in the Hybrid IP-PBX, the ALARM indicator on
the front of the cabinet turns on red, and the system logs the error information.
When the error conditions indicated by the error codes "021", "091", "092", "230", and "510" are recovered,
the ALARM indicator will turn off automatically, indicating successful troubleshooting. When other errors are
logged, the ALARM indicator will turn off only when the log for major or minor errors is cleared from the KX-
TDA Maintenance Console.
In other words, the ALARM indicator will turn off under the following conditions:
•
When the errors "021", "091", "092", "230", and "510" are logged: when the error conditions
are recovered
•
When other errors are logged: when the log for major or minor errors is cleared from the KX-TDA
Maintenance Console
LPR (Optional Service Card with Local Processor) Initial Self Diagnosis
Error Code
Error Message
PROBABLE CAUSE
SOLUTION
211
Speech path
loop-back check
error
•
Optional service card
malfunction: DHLC, DLC,
SLC, CSIF, LCOT, T1, E1,
BRI, PRI, OPB3, E&M, IP-
GW, DID
•
See if the corresponding optional
service card is installed properly
•
Pull out and re-insert the
corresponding optional service card
•
Press the Reset Button
•
Replace the corresponding optional
service card
212
Echo canceller
access error
•
Optional service card
malfunction: CSIF, ECHO
214
DSP Boot check
error
•
Optional service card
malfunction: T1, E1
215
Framer IC access
error
•
Optional service card
malfunction: T1, E1, BRI, PRI
216
MSG card DSP
error
•
Optional service card
malfunction: MSG, OPB3
217
MSG card data
error
•
Optional service card
malfunction: MSG, OPB3
•
Erroneous recording of
messages
•
See if the corresponding optional
service card is installed properly
•
Pull out and re-insert the
corresponding optional service card
•
Press the Reset Button
•
Re-record the messages
•
Replace the corresponding optional
service card