2.7 Connection of Extensions

Installation Manual

139

2.7.3

Digital EXtra Device Port (Digital XDP) Connection

A DPT can be connected to another DPT on the Digital XDP connection. In addition, if the DPT is connected
to a DHLC8 card, it can also have an SLT connected in Parallel mode or XDP mode.

Notes

Both DPTs must be KX-T7600 series DPTs (excluding KX-T7640).

Parallel mode or XDP mode can be selected through system programming.

If XDP mode is enabled through system programming, parallel connection is not possible. Refer to
"1.10.9 Parallelled Telephone" and "2.1.1 Extension Port Configuration" in the Feature Guide for
further information.

With KX-T7600 Series DPT (except KX-T7600E Series)

Using a Modular T-Adaptor

To DLC8/DLC16 card

To DHLC8 card
(for connection of SLT)

4-conductor wiring cord
Connect pins "D1" and "D2".

Slave DPT

SLT

Master DPT

Modular
T-Adaptor

4-conductor wiring cord
Connect pins "D1" and
"D2".

2-conductor wiring cord
Connect pins "T" and "R".

Slave DPT

Master DPT

TO MAIN UNIT

/ PABX

TO TEL

TO MAIN UNIT
/ PABX

Cable

Maximum Distance

ø 0.4 mm:

Under 30 m

ø 0.5 mm:

Under 50 m

ø 0.6 mm:

Under 60 m

CAT 5:

Under 50 m

Back View of DPTs

To DLC8/DLC16 card

To DHLC8 card
(for connection of SLT)