Power supply unit selection – D-Link KX-TDA100 User Manual
Page 34
1.4 Specifications
34
Installation Manual
Calculation Example (KX-TDA100)
The total MEC figure is 88. As this exceeds 64, you need to install an MEC card for this configuration.
Power Supply Unit Selection
The Hybrid IP-PBX needs an optional power supply unit (PSU) suitable for its configuration. Calculate the
load figure from the type and number of items of equipment to be connected, and determine the type of PSU
that will be required.
Load Figure Calculation
Extension Card
*1
DHLC8
8
SLC8
8
SLC16
16
MSLC16
16
CS (1 unit)
0
PT-interface CS (1 unit)
0
ISDN Extension
0
VPS (1 port)
1
*1
Only the extension cards that can support SLTs count for the MEC figures.
Equipment Type
MEC Figure
KX-T7600 series DPT
48 units
48
SLC16
1 card
16
MSLC16
1 card
16
VPS
8 ports
8
Total
88
Equipment Type
Load Figure
PT
KX-T7600 series DPT/DSS console
1
KX-T7560/KX-T7565 DPT
1
Other DPT/DSS console
4
APT
4
IP-PT
0
Extension Card
*1
DHLC8
8
SLC8
8
SLC16
16
MSLC16
16
Equipment Type
MEC Figure