beautypg.com

2 parallel connection of the extensions, With apt with dpt – D-Link KX-TDA100 User Manual

Page 137

background image

2.7 Connection of Extensions

Installation Manual

137

2.7.2

Parallel Connection of the Extensions

Any SLT can be connected in parallel with an APT or a DPT as follows.

Note

In addition to an SLT, an answering machine, a fax machine or a modem (PC) can be connected in
parallel with an APT or a DPT.

With APT

With DPT

Parallel mode or eXtra Device Port (XDP) mode can be selected through system programming.

If the XDP mode is enabled through system programming, parallel connection is not possible. Refer to
"1.10.9 Parallelled Telephone" and "2.1.1 Extension Port Configuration" in the Feature Guide for further
information.

Using a Modular T-Adaptor

To DHLC8 card

4-conductor wiring cord
Connect pins "T", "R", "D1",
and "D2".

2-conductor wiring cord
Connect pins "T" and "R".

SLT

APT

Modular
T-Adaptor

To DHLC8 card

SLT

DPT

Modular
T-Adaptor

4-conductor wiring cord
Connect pins "D1" and
"D2".

2-conductor wiring cord
Connect pins "T" and "R".