beautypg.com

5 frame earth connection – D-Link KX-TDA100 User Manual

Page 48

background image

2.2 Installation of the Hybrid IP-PBX

48

Installation Manual

2.2.5

Frame Earth Connection

IMPORTANT

Connect the frame of the Hybrid IP-PBX to earth.

Be sure to comply with applicable local regulations (e.g., law, guidelines).

Proper earthing (connection to earth) is very important to protect the Hybrid IP-PBX from the bad
effects of external noise or to reduce the risk to the user of electrocution in the case of lightning strike.

The earthing wire of the AC cable has an effect against the external noise and lightning strikes, but it
may not be enough to protect the Hybrid IP-PBX. A permanent connection between earth and the earth
terminal of the Hybrid IP-PBX must be made.

1.

Loosen the screw.

2.

Insert an earthing wire (user-
supplied)*.

3.

Tighten the screw.

4.

Connect the earthing wire to
earth.

* For earthing wire, green-and-yellow insulation is required, and the cross-sectional area of the conductor

must be more than 0.75 mm

2

or 18 AWG.

Screw

To earth

Earthing
wire