beautypg.com

2 characteristics – D-Link KX-TDA100 User Manual

Page 29

background image

1.4 Specifications

Installation Manual

29

1.4.2

Characteristics

Terminal Equipment Loop Limit

PT: KX-T7600 series: 90

Ω; all other DPTs/APTs: 40 Ω

SLT: 60

Ω including set

Doorphone: 20

CS: 130

Ω; PT-interface CS: 65 Ω

Minimum Leakage Resistance

15 000

Ω minimum

Maximum Number of Extension
Instruments per Line

1 for PT or SLT

2 by Parallel or eXtra Device Port connection of an APT/DPT and an SLT

3 by Digital eXtra Device Port connection of two DPTs and an SLT

Ring Voltage

75 Vrms at 20 Hz/25 Hz depending on the Ringing Load

Trunk Loop Limit

1600

Ω maximum

Hookswitch Flash/Recall Timing
Range

24 ms to 2032 ms

BRI Cards Internal ISDN Mode

Supply Voltage: 40 V
Power Supply: 4.5 W per 1 line, 10 W per 4 lines (BRI4)

4.5 W per 1 line, 20 W per 8 lines (BRI8)

Power Supply Method: Phantom Power Supply

Door Opener Current Limit

24 V DC/30 V AC, 1 A maximum

External Relay Current Limit

24 V DC/30 V AC, 1 A maximum

External Sensor Current Limit

Power to the external sensor is provided from the EIO4 card and must be
grounded through the EIO4 card. For the connection diagram, refer to
"2.6.4 EIO4 Card". The Hybrid IP-PBX detects input from the sensor when
the signal is under 100

Ω.

Paging Terminal Impedance

600

MOH (Music on Hold) Terminal
Impedance

10 000