System menu, Login, Network sub-menu – Adtec digital Soloist-HD Pro (version 02.07.09) Manual User Manual
Page 14: System, Menu, Login network
System Menu
The following diagram illustrates the structure and flow of the System Menu on the Adtec Soloist HD
Pro device:
Login
Item
Function
Options
API Command
Login
If the front panel is in a ‘logged out’
state, all configurations are read only.
User must login to change values.
N/A
N/A
Login
Duration
Specifies the time-out value for
automatically logging out of the front
panel once a user logs in for security
purposes. Setting a time of 0 disables
automatic logout capabilities
0 - 9 ( minutes ) *.SYSD LDR
Network Sub-menu
Item
Function
Options
API Command
Ethernet
IP Address
IP address of unit on your
network
user-defined using
default is 192.168.10.48
*.SYSD IPA 0
Ethernet
IP Mask
Defines the units’ Ethernet
Port relative to the rest of
your network
user-defined using
default is 255.255.255.0
*.SYSD IPM 0
Ethernet
DHCP
Dynamic Host Configuration
Protocol; allows the device
to self-locate network
Ethernet parameters
On (finds own DHCP Address)
Off (defaults to last entered IP
Address)
default is OFF
*.SYSD DHCP 0
GigE IP
Address
GigE IP address of unit on
the network
user-defined using
default is 192.168.20.48
*.SYSD IPA 1
GigE IP
Mask
Defines the units’ GigE Port
relative to the rest of your
network
user-defined using
default is 255.255.255.0
*.SYSD IPM 1
GigE
DHCP
Dynamic Host Configuration
Protocol; allows the device
to self-locate network
Ethernet parameters
On (finds own DHCP Address)
Off (defaults to last entered IP
Address)
default is OFF
*.SYSD DHCP 1
Gateway
IP Address
traffic director for off-LAN
resources
user-defined using
default is 192.168.10.1
*.SYSD GIP